DTSB, DTXB

Digital wire Tension Meter Cylindrical Roller Correctly Measures Tape Tension

The principle of the broadband line tension meter is that the tape to be measured passes through three cylindrical rollers, and the middle measuring wheel senses the tension. It is applicable to the tape while it is traveling or in a static state. The position of the thumb push block of the digital line tension meter is different from that of the pointer type, and has three position functions. Different.
Features
10 Tension ranges available
from 5.0 - 500 cN up to 2.5 - 50 daN / Stationary electronic tension sensor for measuring tensions of textile ribbons, films, foils, fibre bunches etc. / Cylindrical tape rollers with up to max. 41 mm width, one-sided mounting / Tension meter with many functions as turnable display, thickness compensation and possibility of custom made calibrations Special Features
Dual-flanged outer guide rollers with various widths, from 7 mm to 41 mm (single-flanged rollers optional, recommendable if the material being measured is wider than the tape roller)

Tension meter DTSB with large, backlight LCD-display
3 different display modes:
– numeric
– numeric with bargraph
– numeric with graph (Time-Tension)

The display rotates in 90° steps for better reading / New, unique, force reduced material catching system / The tension meter has no material thickness compensator / Automatic „Zero-Setting“ in each measuring position using a special sensor technique / 4 Material memory locations for customer made calibrations / Calibration adjustment for fine tuning of the calibration if material differs from the used calibration material / Programmable MIN- and MAX alarms: indication in the display, if reading is out of limits / High speed data sampling (internal 8 kHz) and recording of MIN-, MAX-, last reading, PEAKS, average and standard deviation/ Selectable units of measurement: cN, daN, g, kg, N, lb / Menu set-up in English or German language / Flexible menu set-up to meet operators demand / Some functions can be password protected
Note: Tension meter DTXB offers additional features, like interface, statistical evaluation on PC and a large internal memory. Standard Features Everything in operator's view:
– the guide rollers
– the measured material
– the readings

Roller shifting mechanism ensure easy acquisition of the running material / Ball-bearing mounted, tape rollers / Rubberized handle provides a secure hold in the operators' hand Tension meter with rugged aluminium housing / LiPo accumulator (approx. 40 hours continuous operation) with AC adapter / CE certified, interference resistant against static electrifications Certificate of Compliance with the order 2.1 according EN 10204 is included / Optionally available: Inspection Certificate 3.1 according EN 10204 with calibration report

                  

When selecting the instrument for your specific application, please keep in mind that:
1. Rollers of different widths are not interchangeable by the user.
2. The roller width should correspond with the width of the material to be measured.
Otherwise incorrect measuring results may occur and the instrument may be damaged.
We have the solution to any tension measuring problem! Please contact us to discuss your application requirements.

To assist you in selecting the right tension meter for your specific application, please furnish:
– Kind and dimensions of the material to be measured
– Expected tension range
– Material sample of about 5 m
Specification
DTSB DTXB Tension range* Mix. Head width** mm Roller width mm
DTSB-500 DTXB-500 5.0- 500.0 cN 0.1 cN 55 7, 10, 15, 20, 30
DTSB-1000 DTXB-1000 50- 1000 cN 1 cN 55 7, 10, 15, 20, 30, 41
DTSB-2000 DTXB-2000 100-2000 cN 1 cN 55 7, 10, 15, 20, 30, 41
DTSB-2500 DTXB-2500 150-2500 cN 1 cN 117 7, 10, 15, 20, 30, 41
DTSB-4000 DTXB-4000 200- 4000 cN 1 cN 55 7, 10, 15, 20, 30, 41
DTSB-5000 DTXB-5000 250- 5000 cN 1 cN 117 7, 10, 15, 20, 30, 41
DTSB-10K DTXB-10K 0.5- 10.00 daN 0.01 daN 117 7, 10, 15, 20, 30
DTSB-20K DTXB-20K 1.0- 20.00 daN 0.01 daN 167 7, 10, 15, 20, 30
DTSB-30K DTXB-30K 1.5- 30.00 daN 0.01 daN 217 7, 10, 15
DTSB-50K DTXB-50K 2.5- 50.00 daN 0.01 daN 217 7, 10
1 cN=1.02g=0.01N;1 daN=1.02Kg=10N
 
Roller width Line speed
v max ..m/min
Roller Material*
7 mm 1000 Hard-coated aluminium
10 mm 1000 Hard-coated aluminium
15 mm 1000 Hard-coated aluminium
20 mm 1000 Hard-coated aluminium
30 mm 1000 Hard-coated aluminium
 
Specification
Calibration: According SCHMIDT factory procedure
Accuracy: From 5 % up to 100 % FS*:
± 0.5 % FS* ± 1 digit
remaining tension range and other calibration materials:
±3 % full scale and ±1 digit
Memory for material curves: 1 for SCHMIDT calibration plus 10 for customized calibrations
Measuring units: Force (switchable): cN, daN, g, kg, N, lb
Thickness (switchable): mm, inch
Overrange: Approx. 10 % FS*, full scale, without accuracy guarantee
Overload protection: 100 % full scale
Measuring principle: Strain gauge bridge
Signal processing: Digital, 16 bit A/D converter
Measuring frequency: Max. 1 kHz (1000 measurings/sec.), intern 8 kHz
Measuring roller deflection: Max. 0.2 mm
Display: Graph LCD
3 different displays: Numeric
Numeric with bargraph
Numeric with graph (time-tension)
Display update rate: Approx. 2 times per second
Memory: MIN, MAX, PEAK, AVG and LAST
(DTXB Series) Output signal: USB
(DTXB Series) Memory: 60.000 values split up to 255 measuring positions
(DTXB Series) Memory modes: 4 memory modes with statistical evaluation
Damping: Adjustable electronic damping (averaging)
Cal. Adjustment: ± 10 steps in 1 % increment
Thickness compensation: Max. 2.5 mm (not available for all models)
Auto power off: Approx. 3 minutes of non-use
Temperature coeffizient: Gain: less than ± 0.01 % FS* /°C
Zero point: less than ± 0.03 % FS* /°C
Temperature range: 10 – 45 °C
Air humidity: 85 % RH, max.
Power supply: LiPo accumulator (approx. 40 h continous use),
charging time approx. 3 1/2 h AC adapter 100 – 240 V AC,
adapter (EU, USA, UK)
Housing material: Die-cast aluminium
Housing dimensions: see Dimensions
Weight, net (gross): Approx. 875 g / 1550 g

Specifications subject to change without notice!