TSL,TSF

Wire tension sensor-modular digital analog output

The modular fixed wire tension sensor is used in optical fiber, carbon fiber, and situations with limited bending wires. With signal amplification/digital display, it can output signals to PLC or computer, monitor the wire tension status at any time, and maintain the uniformity of the production quality.
Features

TSL:5 Tension ranges available  from 0 - 50 cN up to 0 - 1000 cN
Large, smooth running guide rollers for minimized material deflection with 32 mm groove Ø

TSF:6 Tension ranges available from 0 - 50 cN up to 0 - 5000 cN
Large, smooth running guide rollers with 70 mm groove diameter for minimized material deflection.
The outer rollers can be moved downward, in case of non-measurements

Stationary electronic tension sensor for measuring sensitive materials as optical fibres, technical fibres etc. Tension meter for quick and easy mounting.


Special Features
Tension sensor TSL / TSFwith integrated measuring amplifier and high accuracy of 1 % FS
Large bending radius for gentle handling of sensitive material by using smooth running, V-grooved guide rollers, ball-bearing mounted

Various output signals are available:
– analog: 0 – 1 V DC (standard), 0 – 10 V DC (optional)
– current: 4 – 20 mA (optional)
– analog DMS: mV/V (optional)

Easy installation, even afterwards, on existing machines
Easy calibration to customized material by operator – zero and gain calibration is required
Measuring principle – load cell with hight quality strain gauge bridge
Tension sensor TSL with mechanical overload protection


Note: a wide range of custom designed models as well modifications of TSF are available on request. Please contact us with your demand!


Standard Features
Tension sensor TSL / TSF with rugged aluminium housing
Required power supply +15…24 V DC (regulated)
Certificate of Compliance with the order 2.1 according EN 10204 is included
Optionally available: Inspection Certificate 3.1 according EN 10204 with calibration report


For the tension sensor TSL / TSF we offer different display units for one or more sensors, as well as strain gauge amplifier. Find further information at display units and amplifier.


Specification
TSL Available Models
Model Tension Range Measuring Head Width* SCHMIDT Calibration Material**
TSL-50 0 – 50 cN 150 mm PA: 0.12 mm Ø
TSL-100 0 – 100 cN 150 mm PA: 0.12 mm Ø
TSL-200 0 – 200 cN 150 mm PA: 0.12 mm Ø
TSL-500 0 – 500 cN 150 mm PA: 0.20 mm Ø
TSL-1000 0 – 1000 cN 150 mm PA: 0.30 mm Ø



TSF Available Models
Model Tension Range Measuring Head Width* SCHMIDT Calibration Material**
TSF-100 0 – 100 cN 270 mm PA: 0.12 mm Ø
TSF-200 0 – 200 cN 270 mm PA: 0.12 mm Ø
TSF-500 0 – 500 cN 270 mm PA: 0.20 mm Ø
TSF-1000 0 – 1000 cN 270 mm PA: 0.30 mm Ø
TSF-2000 0 – 2000 cN 270 mm PA: 0.50 mm Ø